modelValveReferenceValues
Test for Reference Values in Basic and Specific Valve
Extends from Modelica.Icons.Example.
Information
This test model verifies the safeguards for the reference values
dp_ref and rho_ref in
BasicControlValve and SpecificValveType.
When a valve is parameterized using Kvs,
Cvs_US, or Cvs_UK, the reference values must
remain at their defaults:
dp_ref = 1 barrho_ref = 1000 kg/m3
The model contains correctly parameterized reference valves as well as
valves with modified reference values. The latter use
assertionLevel = AssertionLevel.warning, allowing the
simulation to continue while demonstrating the corresponding assertion
messages.
The test verifies that modifying dp_ref or
rho_ref for standardized flow coefficients is detected,
while valves using the default reference values do not trigger these
assertions.
Components
| Type | Name | Default | Description |
|---|---|---|---|
| ThermofluidStream.DropOfCommons | dropOfCommons | ||
| ThermofluidStream.Boundaries.Source | source | ||
| FlowControl.BasicControlValve | reference | ||
| ThermofluidStream.Processes.FlowResistance | flowResistance | ||
| ThermofluidStream.Boundaries.Sink | sink1 | ||
| ThermofluidStream.Sensors.MultiSensor_Tpm | multiSensor_Tpm2 | ||
| ThermofluidStream.Sensors.MultiSensor_Tpm | multiSensor_Tpm3 | ||
| Modelica.Blocks.Sources.Ramp | ramp | ||
| ThermofluidStream.Boundaries.Source | source1 | ||
| FlowControl.BasicControlValve | dp_ref | ||
| ThermofluidStream.Boundaries.Sink | sink2 | ||
| ThermofluidStream.Sensors.MultiSensor_Tpm | multiSensor_Tpm4 | ||
| ThermofluidStream.Sensors.MultiSensor_Tpm | multiSensor_Tpm5 | ||
| ThermofluidStream.Boundaries.Source | source2 | ||
| FlowControl.BasicControlValve | rho_ref | ||
| ThermofluidStream.Boundaries.Sink | sink3 | ||
| ThermofluidStream.Sensors.MultiSensor_Tpm | multiSensor_Tpm7 | ||
| ThermofluidStream.Sensors.MultiSensor_Tpm | multiSensor_Tpm8 | ||
| Modelica.Blocks.Sources.Constant | const2 | ||
| Processes.FlowResistance | flowResistance6 | ||
| Processes.FlowResistance | flowResistance1 | ||
| Processes.FlowResistance | flowResistance2 | ||
| Processes.FlowResistance | flowResistance3 | ||
| Processes.FlowResistance | flowResistance4 | ||
| Boundaries.Source | source3 | ||
| ThermofluidStream.FlowControl.SpecificValveType | reference1 | ||
| Processes.FlowResistance | flowResistance5 | ||
| Boundaries.Sink | sink4 | ||
| Sensors.MultiSensor_Tpm | multiSensor_Tpm1 | ||
| Sensors.MultiSensor_Tpm | multiSensor_Tpm6 | ||
| Boundaries.Source | source4 | ||
| ThermofluidStream.FlowControl.SpecificValveType | dp_ref1 | ||
| Boundaries.Sink | sink5 | ||
| Sensors.MultiSensor_Tpm | multiSensor_Tpm9 | ||
| Sensors.MultiSensor_Tpm | multiSensor_Tpm10 | ||
| Boundaries.Source | source5 | ||
| ThermofluidStream.FlowControl.SpecificValveType | rho_ref1 | ||
| Boundaries.Sink | sink6 | ||
| Sensors.MultiSensor_Tpm | multiSensor_Tpm11 | ||
| Sensors.MultiSensor_Tpm | multiSensor_Tpm12 | ||
| Processes.FlowResistance | flowResistance7 | ||
| Processes.FlowResistance | flowResistance8 | ||
| Processes.FlowResistance | flowResistance9 | ||
| Processes.FlowResistance | flowResistance10 | ||
| Processes.FlowResistance | flowResistance11 |
Contents
| Name | Description |
|---|---|
| medium |