modelMassFlowRate
Generic mass flow rate source - Overdetermined (1 equation)
Extends from ThermofluidStream.Interfaces.SISOFlow.
Information
Model for specifying the mass flow rate.
The model is locally overdetermined (one extra equation) and therefore must be connected to an underdetermined model (e.g., Sink_free) to ensure that the overall system remains balanced.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Specification | |||
| ValueSpecification | m_flowSpec | ThermofluidStream.Types.ValueSpecification.Fixed | Method for specifying the value of the mass flow rate |
| SI.MassFlowRate | m_flow_fixed | 0 | Fixed mass flow rate |
| Layout › Display parameters | |||
| Boolean | showMassFlowRate | true | = true to show the fixed mass flow rate value m_flow_fixed |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Blocks.Interfaces.RealInput | m_flow_prescribed | Prescribed mass flow rate [kg/s] |
Revisions
-
2026, by Raphael Gebhart (raphael.gebhart@dlr.de):
Initial version.