modelIsothermalReference

Adiabatic process, isothermal reference (incompressible fluid -> T_out_is = T_in), isentropic enthalpy h_out_is = h(p_out, T_in)

Extends from ThermofluidStream.Idealized.Processes.AdiabaticThermodynamicModels.BaseClasses.PartialIncompressibleFluid.

Information

The model computes the outlet specific enthalpy based on:

  • Inlet state
  • Outlet pressure
  • Isentropic efficiency

The model assumes an incompressible fluid (rho = const.) to compute the adiabatic reversible reference process (which implies T = const.). It uses the medium model to calculate the outlet specific enthalpy of the isentropic process h_out_is = h(p_out,T).

Components

TypeNameDefaultDescription
Medium.SpecificEnthalpyh_out_isIsentropic outlet specific enthalpy

Revisions

  • 2026, by Raphael Gebhart (raphael.gebhart@dlr.de):
    Initial version.