modelCalculateCoefficientsFromMeasurements

Determine and print pump coefficients based on measurements

Extends from Modelica.Icons.Example.

Parameters

TypeNameDefaultDescription
ThermofluidStream.Processes.Internal.CentrifugalPump.Measurements.Wilo.Stratos25slash1to4measurements
ThermofluidStream.Processes.Internal.CentrifugalPump.Auxiliaries.InternalCoefficientscThermofluidStream.Processes.Internal.CentrifugalPump.Auxiliaries.internalCoefficientsFromMeasurements(measurements)Pump coefficients internally used in the centrifugal pump model
ThermofluidStream.Processes.Internal.CentrifugalPump.Coefficients.GenericPumpcoefficientsThermofluidStream.Processes.Internal.CentrifugalPump.Auxiliaries.coefficientsFromInternalCoefficients(c)

Revisions

  • May 2025, by Raphael Gebhart (raphael.gebhart@dlr.de):
    Initial version.