functionreferencePressureLoss

Pressure loss function based on reference values

Extends from Internal.FlowResistance.partialPressureLoss.

Information

This function calculates the pressure drop according a reference pressure drop at a reference mass flow rate and reference density.

dp/dp_ref =  rho_ref/rho * (m_flow/m_flow_ref)^m

The correlation can be assumed to be linear (m=1), quadratic (m=2) or with a custom exponent m.

Inputs

TypeNameDefaultDescription
SI.Pressuredp_refReference pressure loss
SI.MassFlowRatem_flow_refReference mass flow rate
SI.Densityrho_refReference density
ThermofluidStream.Processes.Internal.ReferencePressureDropFunctiondp_functionThermofluidStream.Processes.Internal.ReferencePressureDropFunction.linearPressure loss function
Realm1.5Exponent for pressure loss function