functionzetaPressureLoss

Pressure loss coefficient function

Extends from Internal.FlowResistance.partialPressureLoss.

Information

For specific components (armatures, fittings, pipe sections, grids, ...), the pressure loss coefficient is often given in the data sheet.

Together with a given (or calculated) reference area A, the pressure drop can be calculated:

dp := zeta * rho/2 * v^2 = zeta/(2*rho) * m_flow^2/A^2

The square of the mass-flow is regularized using the Modelica.Fluid.Utilities.regSquare function.

Inputs

TypeNameDefaultDescription
RealzetaPressure loss coefficient (dp = zeta*rho/2*v^2)
BooleanfromGeometrytrue= true, if cross-sectional area if calculated from geometry
SI.AreaAModelica.Constants.pi*r*rCross-sectional area