modelDynamicJunctionNM
Splitter/Junction with N inlets and M outlets, taking dynamic pressure into account
Extends from ThermofluidStream.Utilities.DropOfCommonsPlus.
Information
Dynamic multiport N-to-M junction for transient manifold behavior. Use this model in complex distribution/collection nodes where dynamic pressure effects are important.
In general the component has four non-linear equation systems of size 1. This can be resolved by setting Advanced->assumeConstantDensity=true (default: false).
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Boolean | assumeConstantDensity | true | = true, if incompressibility is assumed (use '= false' for Ma > 0.3) |
| Integer | N | 1 | Number of inputs |
| Integer | M | 1 | Number of outputs |
| SI.Area[N] | A_in | Cross section area of inlets | |
| SI.Area[M] | A_out | Cross section area of outlets | |
| Advanced | |||
| SI.Area | A_splitter | 0.1 | Internal cross section of Junction |
| Utilities.Units.Inertance | L | dropOfCommons.L | Inertance of each inlet/outlet |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Interfaces.Inlet[N] | inlets | vector of N inlets | |
| Interfaces.Outlet[M] | outlets | vector of N outlets | |
| DynamicJunctionN | dynamicJunctionN | ||
| DynamicSplitterN | dynamicSplitterN |
Contents
| Name | Description |
|---|---|
| Medium | Medium model |