modelDynamicJunctionNM

Splitter/Junction with N inlets and M outlets, taking dynamic pressure into account

Extends from ThermofluidStream.Utilities.DropOfCommonsPlus.

Information

Dynamic multiport N-to-M junction for transient manifold behavior. Use this model in complex distribution/collection nodes where dynamic pressure effects are important.

In general the component has four non-linear equation systems of size 1. This can be resolved by setting Advanced->assumeConstantDensity=true (default: false).

Parameters

TypeNameDefaultDescription
BooleanassumeConstantDensitytrue= true, if incompressibility is assumed (use '= false' for Ma > 0.3)
IntegerN1Number of inputs
IntegerM1Number of outputs
SI.Area[N]A_inCross section area of inlets
SI.Area[M]A_outCross section area of outlets
Advanced
SI.AreaA_splitter0.1Internal cross section of Junction
Utilities.Units.InertanceLdropOfCommons.LInertance of each inlet/outlet

Components

TypeNameDefaultDescription
Interfaces.Inlet[N]inletsvector of N inlets
Interfaces.Outlet[M]outletsvector of N outlets
DynamicJunctionNdynamicJunctionN
DynamicSplitterNdynamicSplitterN

Contents

NameDescription
MediumMedium model