modelDynamicSplitterN

Splitter with 1 inlet and N outlets, taking dynamic pressure into account

Extends from ThermofluidStream.Utilities.DropOfCommonsPlus.

Information

Dynamic variant of the generic splitter with one upstream connection and N downstream connections. This model accounts for dynamic pressure/momentum effects and is suitable for transient analyses where inertial behavior in branching nodes is relevant. Be aware that dynamic formulations can increase model stiffness and nonlinear complexity.

In general the component has two non-linear equation systems of size 1. This can be resolved by setting Advanced->assumeConstantDensity=true (default: false).

considerInertance

For the parameter considerInertance, refer to Idealized.UsersGuide.InertanceNeglect.

Parameters

TypeNameDefaultDescription
BooleanassumeConstantDensitytrue= true, if incompressibility is assumed (use '= false' for Ma > 0.3)
IntegerN1Number of outlets
SI.AreaA_inInlet cross section area
SI.Area[N]A_outCross section area of outlets
Advanced
SI.AreaA_splitter0.1Internal cross section area
BooleanconsiderInertancedropOfCommons.considerInertance=true, if transient momentum (inertance) term is considered; disable only for advanced use
Utilities.Units.InertanceLdropOfCommons.LInertance of each inlet/outlet

Components

TypeNameDefaultDescription
Interfaces.Inletinletinlet
Interfaces.Outlet[N]outletsvector of N outlets
Processes.Nozzlenozzle_in
SplitterNsplitterN
Processes.Nozzle[N]nozzle_out

Contents

NameDescription
MediumMedium model