modelJunctionRatio
Split-ratio Junction for a bypass
Extends from ThermofluidStream.Utilities.DropOfCommonsPlus.
Information
A junction with a fixed mass-flow split. It can be understood to use energy of the higher-pressure inlet to pull the lower-pressure stream (likely to dynamic pressure effects).
For SplitterRatio and JunctionRatio make to only prescribe mass-flow-split in Splitter or Junction.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Boolean | assumeConstantDensity | true | = true, if mixture states are determined by mass flow rates |
| SI.Time | TC_input | 0.05 | Time constant |
| Boolean | invert | false | = true, if splitRatio input is inverted (1-splitRatio) |
| Advanced | |||
| SI.MassFlowRate | m_flow_eps | dropOfCommons.m_flow_reg | Regularization threshold for small mass flows |
| Utilities.Units.Inertance | L | dropOfCommons.L | Inertance of each inlet/outlet |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Interfaces.Outlet | outlet | ||
| Interfaces.Inlet | inletA | ||
| Interfaces.Inlet | inletB | ||
| Modelica.Blocks.Interfaces.RealInput | splitRatio |
Contents
| Name | Description |
|---|---|
| Medium | Medium model |
| mfkprotected |