modelSplitterN
Splitter with one inlet and N outlets
Extends from ThermofluidStream.Utilities.DropOfCommonsPlus.
Information
Generic splitter with one upstream connection and an array of N downstream connections. Use this model to parameterize the number of branches and avoid building large splitter trees manually. This is the recommended approach for scalable network templates.
considerInertance
For the parameter considerInertance, refer to Idealized.UsersGuide.InertanceNeglect.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Integer | N | 1 | Number of outputs |
| Advanced | |||
| Boolean | considerInertance | dropOfCommons.considerInertance | =true, if transient momentum (inertance) term is considered; disable only for advanced use |
| Utilities.Units.Inertance | L | dropOfCommons.L | Inertance of each inlet/outlet |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Interfaces.Inlet | inlet | Inlet | |
| Interfaces.Outlet[N] | outlets | Vector of N outlets |
Contents
| Name | Description |
|---|---|
| Medium | Medium model |
Revisions
-
Mai 2026, by Raphael Gebhart (raphael.gebhart@dlr.de):
Added theconsiderInertanceparameter.