modelSingleSensorSelect

Selectable sensor

Extends from Internal.PartialSensor.

Information

Undirected sensor for a single selectable quantity. For some quatities several units are available.

Parameters

TypeNameDefaultDescription
ThermofluidStream.Sensors.Internal.Types.QuantitiesquantityMeasured quantity
StringquantityStringif quantity == ThermofluidStream.Sensors.Internal.Types.Quantities.T_K then "T in K" elseif quantity == ThermofluidStream.Sensors.Internal.Types.Quantities.T_C then "T in °C" elseif quantity == ThermofluidStream.Sensors.Internal.Types.Quantities.p_Pa then "p in Pa" elseif quantity == ThermofluidStream.Sensors.Internal.Types.Quantities.p_bar then "p in bar" elseif quantity == ThermofluidStream.Sensors.Internal.Types.Quantities.rho_kgpm3 then "d in kg/m3" elseif quantity == ThermofluidStream.Sensors.Internal.Types.Quantities.v_m3pkg then "v in m3/kg" elseif quantity == ThermofluidStream.Sensors.Internal.Types.Quantities.h_Jpkg then "h in J/kg" elseif quantity == ThermofluidStream.Sensors.Internal.Types.Quantities.h_kJpkg then "h in kJ/kg" elseif quantity == ThermofluidStream.Sensors.Internal.Types.Quantities.s_JpkgK then "s in J/(kg.K)" elseif quantity == ThermofluidStream.Sensors.Internal.Types.Quantities.s_kJpkgK then "s in kJ/(kg.K)" elseif quantity == ThermofluidStream.Sensors.Internal.Types.Quantities.a_mps then "Velocity of sound in m/s" elseif quantity == ThermofluidStream.Sensors.Internal.Types.Quantities.cv_JpkgK then "cv in J/(kg.K)" elseif quantity == ThermofluidStream.Sensors.Internal.Types.Quantities.cp_JpkgK then "cp in J/(kg.K)" elseif quantity == ThermofluidStream.Sensors.Internal.Types.Quantities.kappa_1 then "kappa" elseif quantity == ThermofluidStream.Sensors.Internal.Types.Quantities.MM_kgpmol then "M in kg/mol" elseif quantity == ThermofluidStream.Sensors.Internal.Types.Quantities.MM_kgpkmol then "M in kg/kmol" elseif quantity == ThermofluidStream.Sensors.Internal.Types.Quantities.r_Pa then "r in Pa" elseif quantity == ThermofluidStream.Sensors.Internal.Types.Quantities.r_bar then "r in bar" elseif quantity == ThermofluidStream.Sensors.Internal.Types.Quantities.p_total_Pa then "(p+r) in Pa" elseif quantity == ThermofluidStream.Sensors.Internal.Types.Quantities.p_total_bar then "(p+r) in bar" else "error"
Advanced › Regularization
Medium.Densityrho_mindropOfCommons.rho_minMinimum density
Output
BooleanoutputValuefalse= true, if sensor output is enabled
Booleanfilter_outputfalse= true, if sensor output is filtered (to break algebraic loops)
SI.TimeTC0.1Time constant of sensor output filter (PT1)
InitModeinitInitMode.steadyStateInitialization mode for sensor output
Realvalue_00Start value of sensor output

Components

TypeNameDefaultDescription
Modelica.Blocks.Interfaces.RealOutputvalue_outvalueSensor output connector
Realvalue