modelSlackBoundary

Slack Bus in TransiEnt
Diagram of SlackBoundary

Extends from TransiEnt.Components.Boundaries.Electrical.Base.PartialModelPowerBoundary, TransiEnt.Basics.Icons.ElectricSource (Icon for runnable examples).

Information

1. Purpose of model

Model for slack bus when using ComplexPowerPort for LoadFlowCalculations

2. Level of detail, physical effects considered, and physical insight

>L1E (defined in the CodingConventions), Voltage (magnitude and angle) are fixed

3. Limits of validity

stationary component that balances active and reactive power perfectly

4. Interfaces

ComplexPowerPort epp

5. Nomenclature

P_gen "Active Power of Plant, Load Flow"

Q_gen "Reactive Power of Plant, Load Flow"

6. Governing Equations

(no equations)

7. Remarks for Usage

Use for stationary load flow calculations

8. Validation

validated by Jan-Peter Heckel (jan.heckel@tuhh.de)

9. References

(no remarks)

10. Version History

Model created by Jan-Peter Heckel (jan.heckel@tuhh.de) in January 2018

Input connector added in April 2019

Parameters

TypeNameDefaultDescription
Modelica.Units.SI.Voltagev_gensimCenter.v_nVoltage of Plant, controlled by generator
Modelica.Units.SI.Frequencyf_nsimCenter.f_nNominal frequency
Modelica.Units.SI.Angledelta_slackgen0
BooleanuseInputConnectorvfalseGets parameter v from input connector
BooleanuseInputConnectorffalseGets parameter f_n from input connector

Connectors

TypeNameDefaultDescription
TransiEnt.Basics.Interfaces.Electrical.ActivePowerPortepp (from PartialModelPowerBoundary)
TransiEnt.Basics.Interfaces.Electrical.VoltageInv_gen_setfixed votlage input
TransiEnt.Basics.Interfaces.Electrical.FrequencyInf_gen_setfixed frequency input

Components

TypeNameDefaultDescription
TransiEnt.SimCentersimCenter
Modelica.Units.SI.ActivePowerP_genActive Power of Plant, Load Flow
Modelica.Units.SI.ReactivePowerQ_genReactive Power of Plant, Load Flow