modelValveDesiredPressureBefore
Simple valve with desired pressure before the valve
Extends from TransiEnt.Basics.Icons.Valve.
Information
1. Purpose of model
This model represents a simple valve for real gases which ensures a constant pressure at the inlet.
2. Level of detail, physical effects considered, and physical insight
This model works like an ideally controlled valve to ensure a constant inlet pressure.
3. Limits of validity
This model is only valid for real gases and if the changes of the inlet pressure are very small.
4. Interfaces
gasPortIn: Inlet of the real gas
gasPortOut: Outlet of the real gas
5. Nomenclature
(no elements)
6. Governing Equations
(no remarks)
7. Remarks for Usage
Make sure that the inlet pressure is always higher than the outlet pressure to ensure a physically possible use of the valve.
8. Validation
(no remarks)
9. References
(no remarks)
10. Version History
Model created by Carsten Bode (c.bode@tuhh.de) on Tue Apr 05 2016
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Fundamental Definitions | |||
| TILMedia.VLEFluidTypes.BaseVLEFluid | medium | simCenter.gasModel1 | Medium used in the valve |
| SI.Pressure | p_BeforeValveDes | 30e5 | Desired pressure before the valve |
| Summary | |||
| Boolean | useFluidModelsForSummary | false | True, if fluid models shall be used for the summary |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| TransiEnt.Basics.Interfaces.Gas.RealGasPortIn | gasPortIn | ||
| TransiEnt.Basics.Interfaces.Gas.RealGasPortOut | gasPortOut |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| TransiEnt.SimCenter | simCenter | ||