modelValveDesiredPressureBefore

Simple valve with desired pressure before the valve
Diagram of ValveDesiredPressureBefore

Extends from TransiEnt.Basics.Icons.Valve.

Information

1. Purpose of model

This model represents a simple valve for real gases which ensures a constant pressure at the inlet.

2. Level of detail, physical effects considered, and physical insight

This model works like an ideally controlled valve to ensure a constant inlet pressure.

3. Limits of validity

This model is only valid for real gases and if the changes of the inlet pressure are very small.

4. Interfaces

gasPortIn: Inlet of the real gas

gasPortOut: Outlet of the real gas

5. Nomenclature

(no elements)

6. Governing Equations

(no remarks)

7. Remarks for Usage

Make sure that the inlet pressure is always higher than the outlet pressure to ensure a physically possible use of the valve.

8. Validation

(no remarks)

9. References

(no remarks)

10. Version History

Model created by Carsten Bode (c.bode@tuhh.de) on Tue Apr 05 2016