modelPipeGasAdvanced_L4
Pipe for gaseous media with dynamic mass balance and thermal insulation
Extends from ClaRa.Basics.Icons.Pipe_L4.
Information
1. Purpose of model
Pipe model using the advanced gas control volumes with dynamic momentum balance from the ClaRa and a thermal insulation model.
2. Level of detail, physical effects considered, and physical insight
(no remarks)
3. Limits of validity
(no remarks)
4. Interfaces
- Fluid Inlet
- Fluidr Outlet
5. Nomenclature
(no remarks)
6. Governing Equations
(no remarks)
7. Remarks for Usage
(no remarks)
8. Validation
(no remarks)
9. References
(no remarks)
10. Version History
First Version in 04.2020 for the research project Future Energy Solution (FES) by Michael von der Heyde (heyde@tuhh.de)
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Initialisation | |||
| Boolean | useHomotopy | simCenter.useHomotopy | True, if homotopy method is used during initialisation |
| ClaRa.Basics.Units.Temperature[N_cv] | T_start | fill(simCenter.T_amb_start, N_cv) | Start value of system Temperature |
| ClaRa.Basics.Units.Pressure[N_cv] | p_start | fill(simCenter.p_amb_start, N_cv) | Start value of sytsem pressure |
| ClaRa.Basics.Units.MassFraction[medium_fluid.nc - 1] | xi_start | simCenter.airModel.xi_default | Start value of shell mass fraction |
| Integer | initOption | 0 | Type of shell initialisation |
| Fundamental Definitions | |||
| TILMedia.GasTypes.BaseGas | medium_fluid | simCenter.airModel | Medium to be used for gas flow |
| Integer | N_cv | 3 | Number of control volumes |
| Geometry | |||
| ClaRa.Basics.Units.Length | length | 10 | Pipe Length |
| ClaRa.Basics.Units.Length | diameter | 1 | Pipe Diameter |
| ClaRa.Basics.Units.Length | wall_thickness | 0.005 | Pipe Wall Thickness |
| Integer | N_pipes | 1 | Number of Pipes in parallel |
| Boolean | frictionAtInlet | false | True if pressure loss between first cell and inlet shall be considered |
| Boolean | frictionAtOutlet | false | True if pressure loss between last cell and outlet shall be considered |
| ClaRa.Basics.Units.Length | z_in | 1 | Inlet position from bottom |
| ClaRa.Basics.Units.Length | z_out | 1 | Outlet position from bottom |
| Nominal Values | |||
| ClaRa.Basics.Units.MassFlowRate | m_flow_nom | 10 | Nominal mass flow |
| ClaRa.Basics.Units.Pressure | p_nom | simCenter.p_amb_start | Nominal pressure |
| Basics.Units.Pressure | Delta_p_nom | 100 | Nominal pressure loss |
| Basics.Units.Temperature | T_nom | simCenter.T_amb_start | Nominal temperature |
| Summary and Visualisation | |||
| Boolean | showData | false | True if a data port containing p,T,h,s,m_flow shall be shown, else false |
| Boolean | showExpertSummary | simCenter.showExpertSummary | True, if expert summary should be applied |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| ClaRa.Basics.Interfaces.GasPortIn | inlet | ||
| ClaRa.Basics.Interfaces.GasPortOut | outlet |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| TransiEnt.SimCenter | simCenter | ||
| ClaRa.Basics.ControlVolumes.GasVolumes.VolumeGas_L4_advanced | airVolume | ||
| ClaRa.Basics.ControlVolumes.SolidVolumes.CylindricalThinWall_L4 | cylindricalThinWall_L4_1 | ||
| Insulation | insulation | ||
| Summary | summary |
Contents
| Name | Description |
|---|---|
| medium_wall |