modelPipeGasAdvanced_L4

Pipe for gaseous media with dynamic mass balance and thermal insulation
Diagram of PipeGasAdvanced_L4

Extends from ClaRa.Basics.Icons.Pipe_L4.

Information

1. Purpose of model

Pipe model using the advanced gas control volumes with dynamic momentum balance from the ClaRa and a thermal insulation model.

2. Level of detail, physical effects considered, and physical insight

(no remarks)


3. Limits of validity

(no remarks)

4. Interfaces

  1. Fluid Inlet
  2. Fluidr Outlet

5. Nomenclature

(no remarks)

6. Governing Equations

(no remarks)

7. Remarks for Usage

(no remarks)

8. Validation

(no remarks)

9. References

(no remarks)

10. Version History

First Version in 04.2020 for the research project Future Energy Solution (FES) by Michael von der Heyde (heyde@tuhh.de)

Parameters

TypeNameDefaultDescription
Initialisation
BooleanuseHomotopysimCenter.useHomotopyTrue, if homotopy method is used during initialisation
ClaRa.Basics.Units.Temperature[N_cv]T_startfill(simCenter.T_amb_start, N_cv)Start value of system Temperature
ClaRa.Basics.Units.Pressure[N_cv]p_startfill(simCenter.p_amb_start, N_cv)Start value of sytsem pressure
ClaRa.Basics.Units.MassFraction[medium_fluid.nc - 1]xi_startsimCenter.airModel.xi_defaultStart value of shell mass fraction
IntegerinitOption0Type of shell initialisation
Fundamental Definitions
TILMedia.GasTypes.BaseGasmedium_fluidsimCenter.airModelMedium to be used for gas flow
IntegerN_cv3Number of control volumes
Geometry
ClaRa.Basics.Units.Lengthlength10Pipe Length
ClaRa.Basics.Units.Lengthdiameter1Pipe Diameter
ClaRa.Basics.Units.Lengthwall_thickness0.005Pipe Wall Thickness
IntegerN_pipes1Number of Pipes in parallel
BooleanfrictionAtInletfalseTrue if pressure loss between first cell and inlet shall be considered
BooleanfrictionAtOutletfalseTrue if pressure loss between last cell and outlet shall be considered
ClaRa.Basics.Units.Lengthz_in1Inlet position from bottom
ClaRa.Basics.Units.Lengthz_out1Outlet position from bottom
Nominal Values
ClaRa.Basics.Units.MassFlowRatem_flow_nom10Nominal mass flow
ClaRa.Basics.Units.Pressurep_nomsimCenter.p_amb_startNominal pressure
Basics.Units.PressureDelta_p_nom100Nominal pressure loss
Basics.Units.TemperatureT_nomsimCenter.T_amb_startNominal temperature
Summary and Visualisation
BooleanshowDatafalseTrue if a data port containing p,T,h,s,m_flow shall be shown, else false
BooleanshowExpertSummarysimCenter.showExpertSummaryTrue, if expert summary should be applied

Connectors

TypeNameDefaultDescription
ClaRa.Basics.Interfaces.GasPortIninlet
ClaRa.Basics.Interfaces.GasPortOutoutlet

Components

TypeNameDefaultDescription
TransiEnt.SimCentersimCenter
ClaRa.Basics.ControlVolumes.GasVolumes.VolumeGas_L4_advancedairVolume
ClaRa.Basics.ControlVolumes.SolidVolumes.CylindricalThinWall_L4cylindricalThinWall_L4_1
Insulationinsulation
Summarysummary

Contents

NameDescription
Outline
Summary
PressureLoss
HeatTransfer
Insulation
medium_wall