modelENTSOEThermostat

Frequency dependent thermostat as proposed by ENTSO-E
Diagram of ENTSOEThermostat

Extends from Controller.PartialThermostat (Blueprint for thermostat models).

Information

1. Purpose of model

This is a model of a frequency dependant Thermostat which was proposed by ENTSO-E (European Network of Transmission System Operators for Electricity). Full documentation is not available yet. Please see comments in code or contact author per mail.

2. Level of detail, physical effects considered, and physical insight

(no remarks)

3. Limits of validity

(no remarks)

4. Interfaces

T_is - measured value of controlled Temperature

q - boolean (on/off) signal

epp - Electric Power Port for frequency measurement

5. Nomenclature

(no remarks)

6. Governing Equations

(no remarks)

7. Remarks for Usage

(no remarks)

8. Validation

(no remarks)

9. References

(no remarks)

10. Version History

Model created by Pascal Dubucq (dubucq@tuhh.de) on 01.10.2014

Quality check (Code conventions) by Rebekka Denninger on 01.10.2016

Parameters

TypeNameDefaultDescription
SI.TemperatureT_set (from PartialThermostat)279.15Setpoint temperature
SI.TemperatureDifferencedelta (from PartialThermostat)2Hysteresis deadband in K
Booleanq0 (from PartialThermostat)falseThermostat state at startup
SI.Frequencyf_nsimCenter.f_nNominal grid frequency
SI.Frequencydelta_f_db0.4Frequency isWithinDeadband of primary control
Realalpha-10Gain of frequency dependency

Connectors

TypeNameDefaultDescription
TransiEnt.Basics.Interfaces.General.TemperatureInT_is (from PartialThermostat)Measured value of controlled temperature
Modelica.Blocks.Interfaces.BooleanOutputq (from PartialThermostat)Boolean, true=Compressor on
TransiEnt.Basics.Interfaces.Electrical.ActivePowerPorteppElectric power port for frequency measurement

Components

TypeNameDefaultDescription
SI.TemperatureT_set_new (from PartialThermostat)New setpoint
TransiEnt.SimCentersimCenter