| SI.HeatFlowRate | Q_flow_n_heatpump (from HeatpumpSystemProperties) | 5.4e3 | |
| SI.HeatFlowRate | Q_flow_n_peakunit (from HeatpumpSystemProperties) | 5.4e3 | |
| SI.Volume | V_stor_dhw (from HeatpumpSystemProperties) | 0.4 | |
| SI.Volume | V_stor_fh (from HeatpumpSystemProperties) | 0.7 | |
| Real | COP_n_heatpump (from HeatpumpSystemProperties) | 3.7 | COP at nominal conditions |
| Real | eta_peakunit (from HeatpumpSystemProperties) | 0.98 | COP of peak unit |
| SI.Temperature | T_room_start (from HeatpumpSystemProperties) | T_room_set | |
| SI.Temperature | T_stor_dhw_start (from HeatpumpSystemProperties) | T_stor_dhw_set | |
| SI.Temperature | T_stor_fh_start (from HeatpumpSystemProperties) | T_stor_fh_set | |
| TransiEnt.Basics.Types.DoubleSetpointControllerStatus | PLInitStatus (from HeatpumpSystemProperties) | TransiEnt.Basics.Types.off | Used only, if peak load two point control model |
| TransiEnt.Basics.Types.OnOffRelaisStatus | HPInitStatus (from HeatpumpSystemProperties) | TransiEnt.Basics.Types.on_ready | Used only if time relais model |
| SI.Temperature | T_room_set (from HeatpumpSystemProperties) | 273.15 + 20 | |
| SI.Temperature | T_stor_dhw_set (from HeatpumpSystemProperties) | 273.15 + 53 | |
| SI.Temperature | T_stor_fh_set (from HeatpumpSystemProperties) | 273.15 + 35 | |
| SI.Temperature | T_bivalent (from HeatpumpSystemProperties) | 273.15 - 8 | Temperature where bivalent system switches between peak and base load unit |
| SI.TemperatureDifference | DTdb_heatpump (from HeatpumpSystemProperties) | 2 | Deadband of heatpump controller hysteresis |
| Real | T_ref_degC (from HeatpumpSystemProperties) | -12 | |
| Real | T_feed_ref_degC (from HeatpumpSystemProperties) | 33 | |
| Real | T_lim_degC (from HeatpumpSystemProperties) | 19 | Heating limit in degC |
| Real | T_feed_lim_degC (from HeatpumpSystemProperties) | 20 | |
| SI.Time | t_min_on_heatpump (from HeatpumpSystemProperties) | 360 | Minimum uptime |
| SI.Time | t_min_off_heatpump (from HeatpumpSystemProperties) | t_min_on_heatpump | Minimum downtime |
| Modelica.Units.SI.HeatCapacity | C_room (from HeatpumpSystemProperties) | 3.97e7 | Heat capacity of storage (= cp*m) |
| Modelica.Units.SI.ThermalConductance | G_loss (from HeatpumpSystemProperties) | 102 | Constant thermal conductance of material |
| TransiEnt.Basics.Types.HotWaterProfile | HowWaterDrawProfile (from HeatpumpSystemProperties) | TransiEnt.Basics.Types.HotWaterProfile_threePersonBath | |
| Integer | nPar | 24 | |
| Real | A | | Input Matrix for Heat Pump Properties |