modelTransmissionLine
Universal Transmission Line to connect components on the 380kV level, specifically Superstructure components
Extends from TransiEnt.Basics.Icons.Model (Icon for models).
Information
1. Purpose of model
Model of an transmission line to connect components with a differing voltage level of the transmission line.
2. Level of detail, physical effects considered, and physical insight
see PiModelComplex_advanced and SimpleTransformerComplex
3. Limits of validity
(Description)
4. Interfaces
Two ComplexPowerPort for each terminal of the transmission line
5. Nomenclature
(no elements)
6. Governing Equations
(no equations)
7. Remarks for Usage
(none)
8. Validation
(no validation or testing necessary)
9. References
(none)
10. Version History
Model created by Jon Babst (babst@xrg-simulation.de), 06.09.2021
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Fundamental Definitions | |||
| Boolean | hasTransformers | false | Activate voltage transformation at each end of the power line |
| SI.Voltage | U_S | 220*1e3 | voltage level of transmission line |
| Boolean | activateSwitch | false | |
| Integer | ChooseVoltageLevel | 3 | Choose Voltage Level |
| Real | p | 1 | Number of parallel lines |
| Boolean | calculateOverload | true | choose if boolean variable 'overload' is calculated' |
| cable properties | |||
| TransiEnt.Basics.Units.SpecificResistance | r_custom | 0.06e-3 | Resistance load per unit length |
| TransiEnt.Basics.Units.SpecificReactance | x_custom | 0.301e-3 | Reactance load per unit length |
| TransiEnt.Basics.Units.SpecificCapacitance | c_custom | 0.0125e-9 | Capacitance load per unit length |
| SI.Current | i_r_custom | 1290 | Rated current |
| TransiEnt.Components.Electrical.Grid.Characteristics.LVCabletypes | LVCableType | TransiEnt.Components.Electrical.Grid.Characteristics.LVCabletypes.K1 | Type of low voltage cable |
| TransiEnt.Components.Electrical.Grid.Characteristics.MVCabletypes | MVCableType | TransiEnt.Components.Electrical.Grid.Characteristics.MVCabletypes.L1 | Type of Medium voltage cable |
| TransiEnt.Components.Electrical.Grid.Characteristics.HVCabletypes | HVCableType | TransiEnt.Components.Electrical.Grid.Characteristics.HVCabletypes.L1 | Type of high voltage cable |
| SI.Length | l | 1 | Cable LengthCable Length |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Blocks.Interfaces.BooleanInput | switched_input | ||
| TransiEnt.Basics.Interfaces.Electrical.ComplexPowerPort | epp_p | ||
| TransiEnt.Basics.Interfaces.Electrical.ComplexPowerPort | epp_n |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| TransiEnt.SimCenter | simCenter | ||
| TransiEnt.Components.Electrical.Grid.PiModelComplex_advanced | transmissionLine | ||
| TransiEnt.Components.Electrical.PowerTransformation.SimpleTransformerComplex | simpleTransformerComplex_n | ||
| TransiEnt.Components.Electrical.PowerTransformation.SimpleTransformerComplex | simpleTransformerComplex_p |