modelTwoBlockCHP

Example model of plants consisting of several units
Diagram of TwoBlockCHP

Extends from TransiEnt.Basics.Icons.SteamCyclewHeatingCondenser2Blocks.

Information

1. Purpose of model

This model illustrates the use of several units located at a single feed-in site.

2. Level of detail, physical effects considered, and physical insight

(no remarks)

3. Limits of validity

(no remarks)

4. Interfaces

eye: Eyeout

P_set_B1: input for electric power in [W]

P_set_B2: input for electric power in [W]

Q_flow_set_B1: input for heatflow rate in [W]

Q_flow_set_B2: input for heatflow rate in [W]

m_flow_set_B1: input for heatflow rate in [W]

m_flow_set_B2: input for heatflow rate in [W]

T_return_B2: input for return temperature in [K]

outlet: FluidPortOut

T_return_B1: input for for return temperatrue in [K]

epp: active power port (choice of power port)

gasPortIn: real gas inlet

eye_Block1: Eyeout

eye_Block2: Eyeout

5. Nomenclature

(no remarks)

6. Governing Equations

(no remarks)

7. Remarks for Usage

(no remarks)

8. Validation

(no remarks)

9. References

(no remarks)

10. Version History

Model modified by Oliver Schülting (oliver.schuelting@tuhh.de) in Nov 2018: added gasPort

Parameters

TypeNameDefaultDescription
Fundamental Definitions
TILMedia.VLEFluidTypes.BaseVLEFluidmediumsimCenter.fluid1Medium to be used
BooleanuseGasPortfalseChoose if gas port is used or not
TILMedia.VLEFluidTypes.BaseVLEFluidmedium_gassimCenter.gasModel1Gas Medium to be used - only if useGasPort==true

Connectors

TypeNameDefaultDescription
Basics.Interfaces.General.EyeOuteye
Basics.Interfaces.Electrical.ElectricPowerInP_set_B1Set power B1
Basics.Interfaces.Electrical.ElectricPowerInP_set_B2Set power B2
Basics.Interfaces.Thermal.HeatFlowRateInQ_flow_set_B1Set heat flow rate B1
Basics.Interfaces.Thermal.HeatFlowRateInQ_flow_set_B2Set heat flow rate B2
TransiEnt.Basics.Interfaces.General.MassFlowRateInm_flow_set_B1Set mass flow rate B1
TransiEnt.Basics.Interfaces.General.MassFlowRateInm_flow_set_B2Set mass flow rate B2
Basics.Interfaces.General.TemperatureInT_return_B2Set return temperature B2
Basics.Interfaces.Thermal.FluidPortOutoutlet
Basics.Interfaces.General.TemperatureInT_return_B1Set return temperature B1
Basics.Interfaces.Electrical.ActivePowerPortepp
Basics.Interfaces.Gas.RealGasPortIngasPortIn
Basics.Interfaces.General.EyeOuteye_Block1
Basics.Interfaces.General.EyeOuteye_Block2

Components

TypeNameDefaultDescription
TransiEnt.SimCentersimCenter
Modelica.Units.SI.PowerP_out_net
Modelica.Units.SI.HeatFlowRateQ_flow_gen
ContinuousCHPBlock_1
ContinuousCHPBlock_2
TransiEnt.Components.Boundaries.FluidFlow.BoundaryVLE_Txim_flowmassflow_Tm_flow4
TransiEnt.Components.Boundaries.FluidFlow.BoundaryVLE_Txim_flowmassflow_Tm_flow3
Components.Visualization.InfoBoxLargeCHPinfoBoxLargeCHP2
Components.Visualization.InfoBoxLargeCHPinfoBoxLargeCHP3
Components.Sensors.TemperatureSensorT_out_sensor
Components.Sensors.TemperatureSensorT_in_sensor