modelPhotovoltaicProfilePlant

Ideal continuous photovoltaic plant that produces exactly what the connected profile prescribes and adds to global statistics
Diagram of PhotovoltaicProfilePlant

Extends from TransiEnt.Producer.Electrical.Base.IdealInverterPlant (Ideal plant model for inverter coupled plants (i.e. no reaction to grid frequency)), TransiEnt.Basics.Icons.SolarElectricalModel.

Information

1. Purpose of model

Ideal continuous photovoltaic plant that produces exactly what the connected profile prescribes and adds to global statistics.

2. Level of detail, physical effects considered, and physical insight

L1E Models are based on characteristic lines, gains or efficiencies.

The input is directly the output power.

3. Limits of validity

no losses, no physical insight

4. Interfaces

epp: choice of power port

P_el_set: setpoint for electric power in [W]

5. Nomenclature

(no remarks)

6. Governing Equations

(no remarks)

7. Remarks for Usage

(no remarks)

8. Validation

Tested in check model "TransiEnt.Producer.Electrical.Photovoltaics.Check.Check_PhotovoltaicProfilePlant"

9. References

(no remarks)

10. Version History

Model created by Pascal Dubucq (dubucq@tuhh.de) on 01.10.2014

Parameters

TypeNameDefaultDescription
IntegernSubgrids (from PartialElectricPowerPlant)simCenter.iDetailedGridFor calculation of statistics in subgrids (=1 local grid, e.g. hamburg, =2 surrounding grid, e.g. UCTE grid
Physical Constraints
Modelica.Units.SI.PowerP_el_n (from PartialElectricPowerPlant)300e6Nominal power of plant
Statistics
Modelica.Units.SI.Efficiencyeta_total (from PartialElectricPowerPlant)0.6Total efficiency of plant for emission calculation
EnergyResourcetypeOfResource (from PartialElectricPowerPlant)EnergyResource.ConventionalType of energy resource for global model statistics
PrimaryEnergyCarriertypeOfPrimaryEnergyCarrier (from PartialElectricPowerPlant)PrimaryEnergyCarrier.BlackCoalType of primary energy carrier for co2 emissions global statistics
BooleanintegrateElPower (from PartialElectricPowerPlant)simCenter.integrateElPowertrue if electric powers shall be integrated
BooleanintegrateCDE (from PartialElectricPowerPlant)simCenter.integrateCDEtrue if CDE shall be integrated
BooleancalculateCost (from PartialElectricPowerPlant)simCenter.calculateCosttrue if costs shall be calculated

Connectors

TypeNameDefaultDescription
TransiEnt.Basics.Interfaces.Electrical.ActivePowerPortepp (from PartialElectricPowerPlant)
TransiEnt.Basics.Interfaces.Electrical.ElectricPowerInP_el_set (from PartialDispatchablePowerPlant)Electric power setpoint

Components

TypeNameDefaultDescription
TransiEnt.SimCentersimCenter (from PartialElectricPowerPlant)
TransiEnt.ModelStatisticsmodelStatistics (from PartialElectricPowerPlant)
TransiEnt.Components.Statistics.Collectors.LocalCollectors.CollectElectricPowercollectElectricPower (from PartialElectricPowerPlant)
TransiEnt.Components.Statistics.Collectors.LocalCollectors.CollectGwpEmissionsElectriccollectGwpEmissions (from PartialElectricPowerPlant)
TransiEnt.Components.Statistics.Collectors.LocalCollectors.PowerPlantCostcollectCosts (from PartialElectricPowerPlant)
SI.ActivePowerP_el_is (from PartialElectricPowerPlant)-epp.P
RealP_star (from PartialElectricPowerPlant)P_el_is/P_el_n
SI.Efficiencyeta (from PartialElectricPowerPlant)
SI.Timet_fullload (from PartialElectricPowerPlant)E_total_generation/P_el_nfull load time in hours
SI.EnergyE_total_generation (from PartialElectricPowerPlant)Start value for generated electricity statistics
Booleanis_running (from PartialElectricPowerPlant)For continuous plants always true, for discontinous depending on state
SI.EnthalpyFlowRateQ_flow_fuel_is (from PartialElectricPowerPlant)P_el_is/eta
SI.MassFlowRatem_flow_CDE (from PartialElectricPowerPlant)fuelSpecificCO2Emissions.m_flow_CDE_per_Energy*abs(P_el_is)/eta - m_flow_gas_CDE_deposited
SI.MassFlowRatem_flow_gas_CDE_deposited (from PartialElectricPowerPlant)0*time
Realdelta_f_star (from PartialElectricPowerPlant)(epp.f - simCenter.f_n)/simCenter.f_n
Realdelta_P_star (from IdealInverterPlant)(P_el_set + P_el_is)/P_el_n
TransiEnt.Components.Boundaries.Electrical.ActivePower.PowerpowerBoundary (from IdealInverterPlant)