modelBatterySystemEfficiency

Typical characteristic line of battery system efficiency (including inverter efficiency)
Diagram of BatterySystemEfficiency

Extends from TransiEnt.Basics.Icons.Block.

Information

1. Purpose of model

Typical characteristic line of battery system efficiency (including inverter efficiency.

2. Level of detail, physical effects considered, and physical insight

(no remarks)

3. Limits of validity

(no remarks)

4. Interfaces

P_is: input for storage power in [W]

eta: output for efficiency while charging/discharging

5. Nomenclature

(no remarks)

6. Governing Equations

(no remarks)

7. Remarks for Usage

(no remarks)

8. Validation

Tested in check model "TransiEnt.Storage.Electrical.Base.Check.TestBatteryEfficiency"

9. References

[1] Arne Dörschlag, "Erbringung von Primärregelleistung durch Kleinbatteriespeicher im Poolverbund unter Berücksichtigung solarer Eigenstromoptimierung", M.S. thesis, Institute of Electric Power Systems and Automation, Hamburg of Technical University, Sep. 2014

10. Version History

Model created by Pascal Dubucq (dubucq@tuhh.de) on 01.10.2014

Quality check (Code conventions) by Rebekka Denninger on 01.10.2016

Parameters

TypeNameDefaultDescription
SI.PowerP_el_n1e3Storage rated power
SI.Efficiencyeta_max1Upper limit of efficiency
SI.Efficiencyeta_min0Upper limit of efficiency
Reala0.1123Approximation parameter (determined experimentally)
Realb1.329Approximation parameter (determined experimentally)
Realc1.284Approximation parameter (determined experimentally)
Reald0.7666Approximation parameter (determined experimentally)

Connectors

TypeNameDefaultDescription
TransiEnt.Basics.Interfaces.Electrical.ElectricPowerInP_isStorage power in W
TransiEnt.Basics.Interfaces.General.EfficiencyOutetaEfficiency while charging / discharging

Components

TypeNameDefaultDescription
Modelica.Units.SI.Efficiencyeta_cycleTotal cycle efficiency (eta_cycle = eta^2)
RealP_star_absabs(P_is/P_el_n)Absolute Storage power in p.u.