modelHeatingElectrode
Simple Heating Electrode with constant efficency
Extends from TransiEnt.Basics.Icons.Model (Icon for models).
Information
1. Purpose of model
Simple model for electrical heating.
2. Level of detail, physical effects considered, and physical insight
Purely technical component without physical modeling.
3. Limits of validity
Purely technical component without physical modeling. The model has a constant efficency.
4. Interfaces
epp: gets the electric power for heating
heat: heat flow for heating purpose
5. Nomenclature
eta: defines the efficency. The efficency has to be a value between zero and one. The efficency is constant during a simulation
6. Governing Equations
(no equations)
7. Remarks for Usage
(no remarks)
8. Validation
(no validation)
9. References
(no remarks)
10. Version History
Model created by Tobias Ramm (tobias.ramm@tuhh.de) on Fri Mar 20 2015
Revised and edited by Lisa Andresen (andresen@tuhh.de), Jun 2015
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Real | P_max | 2e6 | |
| Real | eta | 0.95 | Constant efficency |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_b | heat | ||
| TransiEnt.Basics.Interfaces.Electrical.ApparentPowerPort | epp |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| TransiEnt.SimCenter | simCenter | ||
| ClaRa.Components.BoundaryConditions.PrescribedHeatFlowScalar | HeatFlow | ||
| TransiEnt.Components.Sensors.ElectricReactivePower | powerOnEPP | ||
| TransiEnt.Components.Boundaries.Electrical.ApparentPower.FrequencyVoltage | constantPotentialVariableBoundary | ||
| Modelica.Blocks.Math.Gain | efficency | efficency of heating | |
| Modelica.Blocks.Nonlinear.Limiter | limiter |