modelGridElement
Extends from Base.PartialGridCell.
Information
1. Purpose of model
Represents a single element of a street segment with up to two consumers opposite to each other. Not to be used outside of the GridConstructor.
2. Level of detail, physical effects considered, and physical insight
(no remarks)
3. Limits of validity
(no remarks)
4. Interfaces
(no remarks)
5. Nomenclature
(no remarks)
6. Governing Equations
(no remarks)
7. Remarks for Usage
(no remarks)
8. Validation
(no remarks)
9. References
(no remarks)
10. Version History
Model created by Michael Djukow for IntegraNet I, 2017
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Boolean | second_Consumer | true | Activate/Deactivate Building 2 |
| Integer | gas_pipe | 0 | Activate/Deactivate gas pipe independent from gas connectors |
| Integer | activate_consumer_pipes | 0 | Activate/Deactivate gas pipe independent from gas connectors |
| Integer | dhn_main_pipe | 0 | Activate/Deactivate if no DHN is used at Consumer |
| Integer | dhn_consumer_1 | 0 | Activate/Deactivate if no DHN is used at Consumer |
| Integer | dhn_consumer_2 | 0 | Activate/Deactivate if no DHN is used at Consumer |
| Connectors | |||
| Boolean | gas_in (from PartialGridCell) | true | Activate/Deactivate inlet gas connector |
| Boolean | gas_out (from PartialGridCell) | true | Activate/Deactivate outlet gas connector |
| Boolean | el_in (from PartialGridCell) | true | Activate/Deactivate inlet electric connector |
| Boolean | el_out (from PartialGridCell) | true | Activate/Deactivate outlet electric connector |
| Boolean | dhn_in_s (from PartialGridCell) | false | Activate/Deactivate inlet dhn connector for supply line |
| Boolean | dhn_out_s (from PartialGridCell) | false | Activate/Deactivate outlet dhn connector for supply line |
| Boolean | dhn_in_r (from PartialGridCell) | false | Activate/Deactivate inlet dhn connector for return line |
| Boolean | dhn_out_r (from PartialGridCell) | false | Activate/Deactivate outlet dhn connector for return line |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| TransiEnt.Basics.Interfaces.Gas.RealGasPortIn | gasPortIn (from PartialGridCell) | ||
| TransiEnt.Basics.Interfaces.Gas.RealGasPortOut | gasPortOut (from PartialGridCell) | ||
| TransiEnt.Basics.Interfaces.Electrical.ApparentPowerPort | epp_p (from PartialGridCell) | ||
| TransiEnt.Basics.Interfaces.Electrical.ApparentPowerPort | epp_n (from PartialGridCell) | ||
| TransiEnt.Basics.Interfaces.Thermal.FluidPortIn | waterPortIn_supply (from PartialGridCell) | Inlet port | |
| TransiEnt.Basics.Interfaces.Thermal.FluidPortOut | waterPortOut_supply (from PartialGridCell) | Outlet port | |
| TransiEnt.Basics.Interfaces.Thermal.FluidPortOut | waterPortOut_return (from PartialGridCell) | Outlet port | |
| TransiEnt.Basics.Interfaces.Thermal.FluidPortIn | waterPortIn_return (from PartialGridCell) | Inlet port |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| TransiEnt.SimCenter | simCenter (from PartialGridCell) | ||
| Systems_Consumer_1 | Systems_1 | ||
| Systems_Consumer_2 | Systems_2 | ||
| TransiEnt.Components.Electrical.Grid.Line_RL | cable | ||
| TransiEnt.Components.Gas.VolumesValvesFittings.Pipes.PipeFlow_L4_Simple_isoth | gas_Pipe | ||
| TransiEnt.Components.Heat.VolumesValvesFittings.Pipes.DoublePipePair_L2 | main_dhn_pipe | ||
| TransiEnt.Components.Heat.VolumesValvesFittings.Pipes.DoublePipePair_L2 | house_pipe_Consumer_1 | ||
| TransiEnt.Components.Heat.VolumesValvesFittings.Pipes.DoublePipePair_L2 | house_pipe_Consumer_2 | ||
| Modelica.Thermal.HeatTransfer.Sources.PrescribedTemperature | T_ground |
Contents
| Name | Description |
|---|---|