modelGridElement

Diagram of GridElement

Extends from Base.PartialGridCell.

Information

1. Purpose of model

Represents a single element of a street segment with up to two consumers opposite to each other. Not to be used outside of the GridConstructor.

2. Level of detail, physical effects considered, and physical insight

(no remarks)

3. Limits of validity

(no remarks)

4. Interfaces

(no remarks)

5. Nomenclature

(no remarks)

6. Governing Equations

(no remarks)

7. Remarks for Usage

(no remarks)

8. Validation

(no remarks)

9. References

(no remarks)

10. Version History

Model created by Michael Djukow for IntegraNet I, 2017

Parameters

TypeNameDefaultDescription
Booleansecond_ConsumertrueActivate/Deactivate Building 2
Integergas_pipe0Activate/Deactivate gas pipe independent from gas connectors
Integeractivate_consumer_pipes0Activate/Deactivate gas pipe independent from gas connectors
Integerdhn_main_pipe0Activate/Deactivate if no DHN is used at Consumer
Integerdhn_consumer_10Activate/Deactivate if no DHN is used at Consumer
Integerdhn_consumer_20Activate/Deactivate if no DHN is used at Consumer
Connectors
Booleangas_in (from PartialGridCell)trueActivate/Deactivate inlet gas connector
Booleangas_out (from PartialGridCell)trueActivate/Deactivate outlet gas connector
Booleanel_in (from PartialGridCell)trueActivate/Deactivate inlet electric connector
Booleanel_out (from PartialGridCell)trueActivate/Deactivate outlet electric connector
Booleandhn_in_s (from PartialGridCell)falseActivate/Deactivate inlet dhn connector for supply line
Booleandhn_out_s (from PartialGridCell)falseActivate/Deactivate outlet dhn connector for supply line
Booleandhn_in_r (from PartialGridCell)falseActivate/Deactivate inlet dhn connector for return line
Booleandhn_out_r (from PartialGridCell)falseActivate/Deactivate outlet dhn connector for return line

Connectors

TypeNameDefaultDescription
TransiEnt.Basics.Interfaces.Gas.RealGasPortIngasPortIn (from PartialGridCell)
TransiEnt.Basics.Interfaces.Gas.RealGasPortOutgasPortOut (from PartialGridCell)
TransiEnt.Basics.Interfaces.Electrical.ApparentPowerPortepp_p (from PartialGridCell)
TransiEnt.Basics.Interfaces.Electrical.ApparentPowerPortepp_n (from PartialGridCell)
TransiEnt.Basics.Interfaces.Thermal.FluidPortInwaterPortIn_supply (from PartialGridCell)Inlet port
TransiEnt.Basics.Interfaces.Thermal.FluidPortOutwaterPortOut_supply (from PartialGridCell)Outlet port
TransiEnt.Basics.Interfaces.Thermal.FluidPortOutwaterPortOut_return (from PartialGridCell)Outlet port
TransiEnt.Basics.Interfaces.Thermal.FluidPortInwaterPortIn_return (from PartialGridCell)Inlet port

Components

TypeNameDefaultDescription
TransiEnt.SimCentersimCenter (from PartialGridCell)
Systems_Consumer_1Systems_1
Systems_Consumer_2Systems_2
TransiEnt.Components.Electrical.Grid.Line_RLcable
TransiEnt.Components.Gas.VolumesValvesFittings.Pipes.PipeFlow_L4_Simple_isothgas_Pipe
TransiEnt.Components.Heat.VolumesValvesFittings.Pipes.DoublePipePair_L2main_dhn_pipe
TransiEnt.Components.Heat.VolumesValvesFittings.Pipes.DoublePipePair_L2house_pipe_Consumer_1
TransiEnt.Components.Heat.VolumesValvesFittings.Pipes.DoublePipePair_L2house_pipe_Consumer_2
Modelica.Thermal.HeatTransfer.Sources.PrescribedTemperatureT_ground

Contents

NameDescription
Demand_Consumer_1
Demand_Consumer_2
Systems_Consumer_1
Systems_Consumer_2