modelZoneR1

Diagram of ZoneR1

Information

Zone room 1 Matisse

Hypothesis and equations

none

Bibliography

none

Instructions for use

Parameter paraMaisonRT allows the user to chose a specific French building regulation for the building, so that building envelope parameters (walls, windows, ventilation...) will be automatically filled with data from the choosen record.

Known limits / Use precautions

none

Validations

Validated model - Amy Lindsay 04/2014

--------------------------------------------------------------
Licensed by EDF under a 3-clause BSD-license
Copyright © EDF 2009 - 2023
BuildSysPro version 3.6.0
Author : Amy LINDSAY, EDF (2014)
--------------------------------------------------------------

Parameters

TypeNameDefaultDescription
IntegerEmplacementAppartement5From 1 to 9, define the position of the apartment : 1 to 3 last floor - 4 à 6 intermediate floor - 7 à 9 : ground floor (from west to east)
Choice of RT
BuildSysPro.BuildingStock.Utilities.Records.BuildingData.CollectiveHousing.BuildingDataMATISSE.BuildingTypeparaMaisonRTFrench building regulation to use
Thermal flows
BooleanGLOEXTfalseIntegration of LW radiation (infrared) toward the environment and the sky
BooleanCLOintPlanchertrueTrue : solar fluxes are absorbed by the floor; False : solar fluxes are absorbed by all the walls and partition walls in proportion of surfaces
BooleanQVinfalseTrue : controlled air change rate; False : constant air change rate
Walls
Modelica.Units.SI.TemperatureTp293.15Initial temperature of walls
BuildSysPro.Utilities.Types.InitCondInitTypeBuildSysPro.Utilities.Types.InitCond.SteadyStateType of initialization for walls
Windows
BooleanuseVoletfalseTrue if shutter, false if not
BooleanuseOuverturefalseTrue if controlled opening, false if not
BooleanuseReductionfalseTrue if solar reduction factors (masking, frame), false if not
Windows › Parameters
IntegerTypeFenetrePF1Choice of type of window or French window
Realvoilage0.95Presence of net curtains : = 0.95 if yes and = 1 if not
Realposition0.90Glazing position: = 0.9 if inner and = 1 if outer
Realrideaux0.85Presence of curtains: = 0.85 if yes and = 1 if not
Realombrages0.85Obstacles shading (vegetation, neighborhood): = 0.85 if yes et = 1 if not
Windows › Reduction factor if useReduction = false
Realr1paraMaisonRT.transmissionMenuiserieFenetresReduction factor for direct radiation if useReduction = false
Realr2paraMaisonRT.transmissionMenuiserieFenetresReduction factor for diffuse radiation if useReduction = false
Thermal bridges
Modelica.Units.SI.ThermalConductanceG_pontsUtilities.Functions.CalculGThermalBridges(ValeursK = paraMaisonRT.ValeursK, LongueursPonts = BuildSysPro.BuildingStock.Utilities.Records.Geometry.CollectiveHousing.SettingsMatisse.LongueursPontsC1, TauPonts = paraMaisonRT.TauPonts)

Connectors

TypeNameDefaultDescription
BuildSysPro.BaseClasses.HeatTransfer.Interfaces.HeatPort_aT_sky
BuildSysPro.BaseClasses.HeatTransfer.Interfaces.HeatPort_aT_ext
BuildSysPro.BaseClasses.HeatTransfer.Interfaces.HeatPort_aT_int_room1
Modelica.Blocks.Interfaces.RealInputRenouvAir
Modelica.Blocks.Interfaces.BooleanInput[1]ouvertureFenetresOpening of north windows
Modelica.Blocks.Interfaces.RealInput[1]fermetureVoletsClosing of north shutters
BuildSysPro.BaseClasses.HeatTransfer.Interfaces.HeatPort_bT_int_commonTemperature of adjacent housings
BuildSysPro.BoundaryConditions.Solar.Interfaces.SolarFluxInput[3]FluxIncExtRoof
BuildSysPro.BoundaryConditions.Solar.Interfaces.SolarFluxInput[3]FluxIncExtNorth
Modelica.Blocks.Interfaces.RealOutputFLUXcloisonChambre2
Modelica.Blocks.Interfaces.RealOutputFLUXcloisonEntree
Modelica.Blocks.Interfaces.RealOutputFLUXcloisonCuisine
Modelica.Blocks.Interfaces.RealInputVENTNord
Modelica.Blocks.Interfaces.RealOutputFLUXporteEntree

Components

TypeNameDefaultDescription
BuildSysPro.BoundaryConditions.Radiation.PintRadDistribPintdistriRad
Modelica.Blocks.Math.MultiSummultiSum
BuildSysPro.Building.AirFlow.HeatTransfer.AirNodenoeudAir
BuildSysPro.Building.AirFlow.HeatTransfer.AirRenewalrenouvellementAir

Revisions

Stéphanie Froidurot - 10/2020 : Add flux for internal doors + correction code