recordMatisse2012_STD

Settings of Matisse collective housing standard 2012

A record of BuildSysPro.BuildingStock.Utilities.Records.BuildingData.CollectiveHousing.BuildingDataMATISSE.BuildingType.

Information

Record of Matisse collective housing settings according to the date of construction

Hypothesis and equations

none

Bibliography

none

Instructions for use

Detail of thermal bridge vectors :

  • TauPonts[1] and ValeursK[1] : exterior wall / common wall
  • TauPonts[2] and ValeursK[2] : unheated room wall / common wall
  • TauPonts[3] and ValeursK[3] : exterior wall / intermediate floor
  • TauPonts[4] and ValeursK[4] : exterior wall / intermediate ceiling
  • TauPonts[5] and ValeursK[5] : unheated room wall / intermediate floor
  • TauPonts[6] and ValeursK[6] : unheated room wall / intermediate ceiling
  • TauPonts[7] and ValeursK[7] : door
  • TauPonts[8] and ValeursK[8] : windows
  • TauPontsPlancher[1] and ValeursKPlancher[1] : intermediate floor / exterior wall of basement
  • TauPontsPlancher[2] and ValeursKPlancher[2] : intermediate floor / unheated room wall of basement
  • TauPontsPlancher[3] and ValeursKPlancher[3] : intermediate floor / common wall of basement
  • TauPontsPlafond[1] and ValeursKPlafond[1] : intermediate ceiling / exterior wall of ceiling
  • TauPontsPlafond[2] and ValeursKPlafond[2] : intermediate ceiling / unheated room wall of ceiling
  • TauPontsPlafond[3] and ValeursKPlafond[3] : intermediate ceiling / common wall of ceiling

Known limits / Use precautions

Warning : thermal bridges have been set to null because of a lack of data, it will be necessary to complete them when more details are available.

Validations

Validated model - Benoît Charrier 12/2015

--------------------------------------------------------------
Licensed by EDF under a 3-clause BSD-license
Copyright © EDF 2009 - 2023
BuildSysPro version 3.6.0
Author : Benoît CHARRIER, EDF (2015)
--------------------------------------------------------------

Attributes

NameValue
UvitrageAF1.5
UvitrageSF1.5
bLNC0.1
bPlancher0.80
bPlafond1
ValeursK{0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00}
TauPonts{1, 1, 1, 1, 1, 1, 1, 1}
ValeursKPlafond{0.00, 0.00, 0.00}
ValeursKPlancher{0.00, 0.00, 0.00}
TauPontsPlafond{1, 1, 1}
TauPontsPlancher{1, 1, 1}
PontsTh_Generique0.00
PontsTh_Bas0.00
PontsTh_Haut0.00
renouvAir0.3
hsExtVert25
hsIntVert7.69
hsExtHor25
hsIntHorHaut10

Revisions

Benoît Charrier 05/2015 : ajout de paramètres nécessaires au modèle MatisseAssemblageLC

Benoît Charrier 06/2017 :

  • editing value of air renewal renouvAir from 0,426 to 0,3 vol/h to fit with a humidity sensitive ventilation system which is commonly used in RT2012
  • editing value of U glazings UvitrageAF and UvitrageSF from 1,2 to 1,5 W/m2.K which is more representative of RT2012
  • setting thermal bridge values to null because actual values are not representative, will need to be adjusted when more data is available