modelSolarThermalCollector

Diagram of SolarThermalCollector

Information

Hypothesis and equations

none

Bibliography

none

Instructions for use

none

Known limits / Use precautions

none

Validations

Validated model - Hubert Blervaque, Sila Filfli 06/2011

--------------------------------------------------------------
Licensed by EDF under a 3-clause BSD-license
Copyright © EDF 2009 - 2023
BuildSysPro version 3.6.0
Author : Hubert BLERVAQUE, Sila FILFLI, EDF (2011)
--------------------------------------------------------------

Parameters

TypeNameDefaultDescription
Orientation of the solar collector
Modelica.Units.NonSI.Angle_degAzimut0Surface azimuth (Orientation relative to the south) - S=0°, E=-90°, W=90°, N=180°
Modelica.Units.NonSI.Angle_degInclinaison30Tilt of the surface relative to the horizontal - toward the ground=180°, toward the sky=0°, vertical=90°
RealAlbedo0.2Albedo of the environment
Characteristics of the solar collector
Modelica.Units.SI.AreaSurface1Surface of the solar collector
RealFacteurOptique0.65Optical factor (generally between 0,5 and 0,9)
RealCoeffTransmission4Transmission coefficient, depends on insulation and nature of the coverage.

Connectors

TypeNameDefaultDescription
Modelica.Blocks.Interfaces.RealInput[10]GSolar data {DIFH, DIRN, DIRH, GLOH, t0, CosDir[1:3], Solar azimuth angle , Solar elevation angle}
BuildSysPro.BaseClasses.HeatTransfer.Interfaces.HeatPort_aT_ext
BuildSysPro.BaseClasses.HeatTransfer.Interfaces.HeatPort_bT_solar

Components

TypeNameDefaultDescription
RealPsol
RealPisolation
BuildSysPro.BoundaryConditions.Solar.Irradiation.FLUXsurfLWRincfLUXsurfGLOH

Revisions

Hubert Blervaque - 07/2012 : Modification du signe de la chaleur récupérée