modelWISC

Test model for WISC (Wind and Infrared Sensitive Collector) - uncovered PVT collectors

Extends from Modelica.Icons.Example.

Information

This example demonstrates the implementation of the IDEAS.Fluid.PVTCollectors.PVTQuasiDynamicCollector for a variable fluid flow rate and weather data from San Francisco, CA, USA.

The collector modeled here is an uncovered PVT collector, also referred to as a WISC (Wind and Infrared Sensitive Collector). These collectors are sensitive to ambient wind and infrared radiation due to the absence of a glazing layer. They can be either unglazed insulated (UI) or unglazed non-insulated (UN), depending on the thermal insulation applied to the back side of the collector.

This test model uses the IDEAS.Fluid.PVTCollectors.Data.Uncovered.UI_Validation record. However, if you know the brand and model of the PVT collector you plan to simulate or install, it is recommended to use the actual datasheet parameters in a custom IDEAS.Fluid.PVTCollectors.Data.GenericQuasiDynamic record.

Parameters

TypeNameDefaultDescription
IDEAS.Fluid.PVTCollectors.Data.Uncovered.UI_ValidationdatPVTCol

Components

TypeNameDefaultDescription
IDEAS.BoundaryConditions.WeatherData.ReaderTMY3weaDatWeather data input file
IDEAS.Fluid.Sources.Boundary_pTsinOutlet for water flow
IDEAS.Fluid.Sensors.TemperatureTwoPortTOutTemperature sensor
IDEAS.Fluid.Sensors.TemperatureTwoPortTInTemperature sensor
Sources.Boundary_pTsouInlet for water flow
Modelica.Blocks.Sources.SinesinePressure source
IDEAS.Fluid.PVTCollectors.PVTCollectorpvtCol

Contents

NameDescription
MediumMedium in the system

Revisions

  • July 7, 2025, by Lone Meertens:
    First implementation PVT model. This is for 1436.