modelGen2
100MVA/13.8kV generation unit for bus 2
Extends from Gen1 (100MVA/18kV generation unit for bus 1).
Information
Note that this 100MVA/13.8kV generation unit allows the user to perform a step disturbance of magnitude height at instant tstart in the voltage reference value for each Automatic Voltage Regulator.
Also note that boolean variable refdisturb needs to be set to true for disturbance to take place.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Real | vf0 (from Gen1) | 1.755517086537914 | Initial field voltage value |
| Real | vref0 (from Gen1) | 1.118023800520641 | Initial terminal voltage reference value |
| Power flow data | |||
| Types.ApparentPower | S_b (from pfComponent) | SysData.S_b | System base power |
| Types.Voltage | V_b (from pfComponent) | 400e3 | Base voltage of the bus |
| Types.Frequency | fn (from pfComponent) | SysData.fn | System frequency |
| Types.ActivePower | P_0 (from pfComponent) | 1e6 | Initial active power |
| Types.ReactivePower | Q_0 (from pfComponent) | 0 | Initial reactive power |
| Types.PerUnit | v_0 (from pfComponent) | 1 | Initial voltage magnitude |
| Types.Angle | angle_0 (from pfComponent) | 0 | Initial voltage angle |
| Boolean | displayPF (from pfComponent) | false | Display power flow: |
| Parameter mask | |||
| Boolean | enableS_b (from pfComponent) | false | Enable S_b in parameter list |
| Boolean | enableV_b (from pfComponent) | false | Enable V_b in parameter list |
| Boolean | enablefn (from pfComponent) | false | Enable fn in parameter list |
| Boolean | enableP_0 (from pfComponent) | false | Enable P_0 in parameter list |
| Boolean | enableQ_0 (from pfComponent) | false | Enable Q_0 in parameter list |
| Boolean | enablev_0 (from pfComponent) | false | Enable v_0 in parameter list |
| Boolean | enableangle_0 (from pfComponent) | false | Enable angle_0 in parameter list |
| Boolean | enabledisplayPF (from pfComponent) | false | Enable displayPF in parameter list |
| AVR Disturbance | |||
| Real | height (from Gen1) | Disturbance magnitude | |
| Real | tstart (from Gen1) | Disturbance time instant | |
| Boolean | refdisturb (from Gen1) | Allow disturbance | |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| OpenIPSL.Interfaces.PwPin | pwPin (from Generator) |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| OpenIPSL.Electrical.SystemBase | SysData (from pfComponent) | Must add this line in all models | |
| Types.ActivePower | P (from Generator) | Active power | |
| Types.ReactivePower | Q (from Generator) | Reactive power | |
| OpenIPSL.Electrical.Machines.PSAT.Order4 | gen (from Gen1) | ||
| OpenIPSL.Electrical.Controls.PSAT.AVR.AVRTypeII | AVR (from Gen1) | ||
| Modelica.Blocks.Sources.Step | step (from Gen1) | ||
| Modelica.Blocks.Logical.Switch | switch1 (from Gen1) | ||
| Modelica.Blocks.Sources.BooleanConstant | booleanConstant (from Gen1) |