modelCISESim2States

CISE plant reduced model with boundary conditions and initial steady-state computation
Diagram of CISESim2States

Information

This model provides the boundary condition values to the CISEPlant2Statesmodel; it can be used to simulate open-loop transients.

The steady state is obtained by setting the derivatives of all the state variables to zero in the initial equation section. The offset values for ValveOpening1 and wfeed1, i.e. the parameters ValveOpening_offset and wfeed_offset have a fixed=false attribute. Their actual values are set by the two additional initial equations specifying the initial drum level and pressure.

The CISESim2States120501 model extends CISESim2States by adding suitable numerical values to the boundary condition signal generators.

Parameters

TypeNameDefaultDescription
SI.MassFlowRatewfeed_offsetOffset of feedwater flow rate
RealValveOpening_offsetOffset of valve opening
SI.PressureInitialDrumPressure5.9359e+006
SI.LengthInitialDrumLevel-0.091

Components

TypeNameDefaultDescription
Models.CISEPlant2StatesPlant
Modelica.Blocks.Sources.ConstantQsh
Modelica.Blocks.Sources.RampQev
Modelica.Blocks.Sources.Rampwfeed1
Modelica.Blocks.Math.Add3wfeed
Modelica.Blocks.Sources.Rampwfeed2
Modelica.Blocks.Sources.RampValveOpening1
Modelica.Blocks.Sources.RampValveOpening2
Modelica.Blocks.Math.Add3sum_1
Modelica.Blocks.Sources.Rampwfeed3
Modelica.Blocks.Sources.Rampwfeed5
Modelica.Blocks.Sources.Rampwfeed4
Modelica.Blocks.Sources.Ramphfeed1
Modelica.Blocks.Sources.Ramphfeed2
Modelica.Blocks.Math.Add3hfeed
Modelica.Blocks.Sources.Ramphfeed3
Modelica.Blocks.Math.AddValveOpening
Systemsystem

Revisions