modelTestSteamGenerator_1SG

Diagram of TestSteamGenerator_1SG

Information

## Copyright © EDF 2002 - 2026   
## ThermoSysPro Version 4.2

Parameters

TypeNameDefaultDescription
Primary
ThermoSysPro.Units.SI.PressureP_Prim155e5
ThermoSysPro.Units.SI.TemperatureThot_Prim320 + 273.15
ThermoSysPro.Units.SI.TemperatureTcold_Prim288.8 + 273.15
ThermoSysPro.Units.SI.MassFlowRateQ_Prim5000Primary side flow rate per SG
Secondary
ThermoSysPro.Units.SI.TemperatureT_Feedwater227 + 273.15
ThermoSysPro.Units.SI.SpecificEnthalpyh_Feedwater977100
ThermoSysPro.Units.SI.MassFlowRateQ_Secondary520Primary side flow rate per SG
ThermoSysPro.Units.SI.PressureP_Secondary67.3e5

Components

TypeNameDefaultDescription
WaterSteam.BoundaryConditions.SinkQsinkQ
WaterSteam.BoundaryConditions.SourcePsourceP
ThermoSysPro.WaterSteam.BoundaryConditions.SourceQsourceQ1
ThermoSysPro.WaterSteam.BoundaryConditions.SinkPsinkP1
ThermoSysPro.WaterSteam.PressureLosses.SingularPressureLosssingularPressureLoss1
WaterSteam.HeatExchangers.SteamGenerator_1SGsteamGenerator
WaterSteam.Sensors.SensorTSensorT_ThotPrim
WaterSteam.Sensors.SensorTSensorT_TcoldPrim
WaterSteam.Sensors.SensorTSensorT_TARE