modelBasicControlValve
Extends from ThermofluidStream.FlowControl.Internal.PartialValve.
Information
This model serves for most incompressible applications where basic control valves are needed.
The modeler has the ability to choose between different valve characteristics and flow coefficients.
The three standard curve characteristics (linear, parabolic, equal-percentage) are implemented and can be chosen.
To conclude the parameterization, a flow coefficient has to be set. Most data sheets of valves deliver a corresponding "KVs (CVs)"-Value. Otherwise a nominal mass-flow rate can be set.
For incompressible flow, the reference values for density (1g/cm3) and pressure (1bar) should be unchanged.
Reference values for standardized flow coefficients
When using Kvs, Cvs_US, or
Cvs_UK, the default values
dp_ref = 1 bar and
rho_ref = 1000 kg/m3 must not be modified.
assertionLevel. To test this behavior, a test model has been setup in ValveReferenceValues.Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Valve parameters | |||
| FlowCoeffType | flowCoefficient | FlowCoeffType.Kvs | Select type of flow coefficient |
| Real | Kvs | 0 | Kvs-value (metric) from data sheet (valve fully open) |
| Real | Cvs_US | 0 | Cvs-value (US [gal/min]) from data sheet (valve fully open) |
| Real | Cvs_UK | 0 | Cvs-value (UK [gal/min]) from data sheet (valve fully open, deprecated; use Kvs or Cvs_US instead) |
| SI.MassFlowRate | m_flow_ref_set | 0 | Reference mass flow rate |
| Advanced | |||
| AssertionLevel | assertionLevel | AssertionLevel.error | Assertion level for invalid reference values |
Contents
| Name | Description |
|---|---|
| valveCharacteristics |