modelSmallScaleCHPsystem
Extends from TransiEnt.Basics.Icons.CHP.
Information
1. Purpose of model
Combination of storage tank, CHP unit, boiler and controller model into one system model with a connection to the electrical and gas grid.
2. Level of detail, physical effects considered, and physical insight
(Purely technical component without physical modeling.)
3. Limits of validity
(Purely technical component without physical modeling.)
4. Interfaces
TransiEnt.Basics.Interfaces.Thermal.HeatFlowRateIn Q_demand
TransiEnt.Basics.Interfaces.Electrical.ApparentPowerPort epp
TransiEnt.Basics.Interfaces.Gas.RealGasPortIn gasPortIn
5. Nomenclature
(no elements)
6. Governing Equations
(no equations)
7. Remarks for Usage
All components use energy based modeling without consideration of heat transfer media.
8. Validation
(no validation or testing necessary)
9. References
(no remarks)
10. Version History
Model created by Anne Hagemeier, Fraunhofer UMSICHT, 2018
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Fundamental Definitions | |||
| TILMedia.VLEFluidTypes.BaseVLEFluid | FuelMedium | simCenter.gasModel1 | Medium to be used for fuel gas |
| Configuration | |||
| SI.SpecificEnthalpy | HoC_fuel | 40e6 | heat of combustion of fuel used |
| Boolean | useGasPort | true | True if gas port shall be used |
| Storage Parameters | |||
| SI.Temperature | T_s_max | 363.15 | Maximum storage temperature |
| SI.Temperature | T_s_min | 303.15 | Minimum storage temperature |
| SI.Temperature | T_start | 353.15 | Start temperature |
| SI.Volume | V_Storage | 0.5 | Volume of the storage |
| SI.Height | height | 1.3 | Height of heat storage |
| SI.Diameter | d | sqrt(4*V_Storage/Modelica.Constants.pi/height) | Diameter of heat storage |
| Modelica.Units.NonSI.Temperature_degC | T_amb | 15 | Assumed constant temperature in tank installation room |
| SI.SurfaceCoefficientOfHeatTransfer | k | 0.08 | Coefficient of heat transfer |
| CHP Parameters | |||
| SI.Power | Q_flow_n_CHP | 4000 | Heat output of CHP |
| SI.Power | P_n_CHP | 8000 | Electric power output of CHP |
| SI.Efficiency | eta_el | 0.3 | Constant electric efficiency of the CHP |
| SI.Efficiency | eta_th | 0.6 | Constant thermal efficiency of the CHP |
| Boiler Parameters | |||
| SI.Efficiency | eta_boiler | 1.05 | Boiler's overall efficiency |
| SI.HeatFlowRate | Q_flow_n_boiler | 20000 | Nominal heating power of the gas boiler |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| PowerPortModel | epp | ||
| TransiEnt.Basics.Interfaces.Gas.RealGasPortIn | gasPortIn | ||
| TransiEnt.Basics.Interfaces.Thermal.HeatFlowRateIn | Q_Demand |
Components
Contents
| Name | Description |
|---|---|