modelCISESim

CISE Plant model with boundary conditions and initial steady-state computation
Diagram of CISESim

Information

This model provides the boundary condition values to the CISEPlantmodel; it can be used to simulate open-loop transients.

The steady state is obtained by setting the derivatives of all the state variables to zero in the initial equation section. The offset values for ValveOpening1 and wfeed1, i.e. the parameters ValveOpening_offset and wfeed_offset have a fixed=false attribute. Their actual values are set by the two additional initial equations specifying the initial drum level and pressure.

The CISESim120501, CISESim180503, CISESim180504 models extend CISESim by adding suitable numerical values to the boundary condition signal generators.

Parameters

TypeNameDefaultDescription
SI.MassFlowRatewfeed_offsetOffset of feedwater flow rate
RealValveOpening_offsetOffset of valve opening
SI.PressureInitialDrumPressure5.9359e+006
SI.LengthInitialDrumLevel-0.091

Components

TypeNameDefaultDescription
Modelica.Blocks.Sources.ConstantQsh
Modelica.Blocks.Sources.RampQev
Modelica.Blocks.Sources.Rampwfeed1
Modelica.Blocks.Math.Add3wfeed
Modelica.Blocks.Sources.Rampwfeed2
Modelica.Blocks.Sources.RampValveOpening1
Modelica.Blocks.Sources.RampValveOpening2
Modelica.Blocks.Math.Add3sum_1
Modelica.Blocks.Sources.Rampwfeed3
Modelica.Blocks.Sources.Rampwfeed5
Modelica.Blocks.Sources.Rampwfeed4
Modelica.Blocks.Sources.Ramphfeed1
Modelica.Blocks.Sources.Ramphfeed2
Modelica.Blocks.Math.Add3hfeed
Modelica.Blocks.Sources.Ramphfeed3
Modelica.Blocks.Math.Addsum_3
Modelica.Blocks.Sources.RampValveOpening3
Modelica.Blocks.Math.AddValveOpening
Systemsystem
Models.CISEPlantPlant

Revisions